Titan Air Incorporated


  • SUMMARY
  • FEATURES
  • SPECIFICATIONS
  • DRAWINGS

Direct-Fired Summary

Titan Air's Direct-Fired product line has been manufactured since 1983 and has maintained leadership in the industry through research and development of new products and further improvement to basic products. In additional to the 100% outside air function, recirculation, variable air volume, and high outlet temperature options are available. Cooling and energy recovery can also be added to fit your application requirements.

Maximum 120F temp rise for NG and LP.

- TA Series Description
- TA Unit & Accessories
- TA Vertical Unit & Accessories
- TA Weights
- TA Standard Temperature Controls

Demand Air | Variable Air Volume

Titan Air's Demand Air unit is a variable air volume unit. Supply air volume is adjusted by a VFD (variable frequency drive) which allows each unit to respond to changing exhaust loads. Many applications control building pressure as exhaust varies. Electrical power consumption drops on a cubed ratio to blower speed and gas consumption also drops, reducing operational costs.

Maximum 100F temp rise for NG and LP.

- TA Series Description
- TA Unit & Accessories
- TA Vertical Unit & Accessories
- TA Weights
- TA Demand Air General Information
- TA Demand Air Example
- TA Standard Temperature Controls

AR Systems | Recirculation

Titan Air's AR system is designed to substantially reduce infiltration of cold air (which accounts for up to 40% of a building's heat loss) and reduce energy requirements considerably. The pressurized heating system creates a slight and even overall pressure that effectively controls infiltration of cold air. The AR system is capable of supplying 100% fresh outside air, or a mixture of fresh and return air. When not in maximum ventilation mode, the system will recirculate building air to reduce energy requirements. Return air does not pass across the direct-fired burner. AR system advantages include high heat efficiency, lower energy use, and greater overall comfort. The AR system when sized properly with building relief helps clean out airborne contaminants and increases indoor air quality.

Maximum 110F temp rise on NG and 90F on LP.

- TA Series Description
- TA AR Unit & Accessories
- TA AR Vertical Unit & Accessories
- TA AR Building Pressurization
- TA AR Pool Example
- TA Standard Temperature Controls

TAP Units

TAP units were designed as indoor units to provide an economical and modular solution for small to medium sized paint booth ventilation and curing operations. These units are versatile enough for other applications. Modular construction makes one burner section suitable for multiple equipment configurations. Indoor vertical units can have the outside air ductwork connected to a choice of three sides of the bottom of the unit. Motor and bearings are outside the airstream allowing a higher discharge temperature and cure temps up to
200 degrees F.

Maximum 120F temp rise on NG and 109F on LP.

- TAP General Information

HOT Units | High Outlet Temperature

Titan Air's ETL listed high outlet temperature 2-speed make-up air system provides heating temperatures in two distinct ranges for superior painting and curing. Cooling and humidity control can also be added for temperature and humidity controlled applications.

Maximum 120F temp rise in spray mode. Unlisted maximum 160F in bake mode.

- HOT Information

TAM Units

Titan Air's TAM units are the solutions for competitively priced and/or short lead time projects. TAM units offer many of the same features of our TA line with the advantage of a compact size, light weight construction, and versatile mounting options.

Maximum 120F temp rise on NG and LP.

- TAM Unit & Accessories

Arrangements

Below are standard arrangements. Additional custom arrangements are available upon request.


 

Direct-Fired Features

Standard Features

Construction

   • ETL Listed
   • Formed G-90 Galvanized base
      < 10,000 CFM
   • Primed welded structural steel base
      > 10,000 CFM
   • G-90 Galvanized Casing
   • Single wall access doors
   • Internally mounted motor, burner,
     and controls
   • Pre-piped, pre-wired, and factory tested
      • Sectioned units may require field
         assembly, wiring, and piping
   • Lifting Provisions
   • Vertical units have additional features
      • Built-in filter sections
      • Built-in 36" stand
      • Ground level electric and manifold
         service access
   • Multiple configurations

Fan & Motor

   • DWDI forward curve industrial type blower(s)
   • Solid turned ground and polished shaft
   • Self aligning bearings
   • Premium E ODP blower motor w/ 1.15      service factor
   • Motor starter & overload protection
   • Adjustable motor base
   • Variable pitch drive up to 30 HP

Burner

   • Midco or Eclipse direct-fired burner
   • ANSI Z83.4 / CSA 3.7 gas train
   • Electronic flame supervision (flame rod      rectification)
   • Air proving burner safety switch
   • High gas pressure switch
   • High temperature limit
   • Ignition transformer

Controls

          • Non-Fused door interlocked disconnect switch
          • Discharge air temperature control, with remote              set-point & summer-off-winter selector switch
          • Auxiliary contacts for exhaust fan interlock
          • Control voltage transformer

Optional Features

Construction

   • Double wall access doors with extruded       aluminum frames (rated to 8" w.c.)
   • 1” 1.5#, 2” 1.5#, 2” 3#, 2" R-7.7, or 2” R-13       insulation
   • Enamel, Epoxy, or Heresite exterior coatings
   • Custom configurations and dimensions
   • Built-in or separate chilled water or DX       cooling coil module
   • Built-in or separate direct evaporative cooler       module
   • Packaged DX cooling
   • Flat plate cell energy recovery section
   • Enthalpy wheel energy recovery section

Accessories

   • Mixing Box
   • Intake air hood w/ bird screen
   • V-Bank intake filters
 • 1" or 2" Cleanable
 • Linked panel MERV-8
 • 2" pleated MERV-8
   • Flat bank final filters
 • 2" Pleated MERV-8
 • 4" Pleated MERV-11 to 14
 • 12" Cartridge MERV-11 to 16
 • Bag Filters MERV-9 to 14
 • 12" Carbon odor control
 • 12" HEPA 99.97 to 99.99%

   • Intake damper (standard or low leak)
   • Discharge damper (standard or low leak)
   • Discharge diffuser
   • Roof curb
   • Service platform
   • Service lights
   • GFI service outlet

Fan & Motor

   • BIDW or AFDW Industrial centrifugal fan
   • BISW or AFSW Industrial centrifugal fan
   • Commercial or industrial plenum fan
   • Commercial or industrial plug fan
   • TEFC, Severe Duty or EXP Motors
   • AMCA A, B, or C Spark Resistant
   • Motor and bearings outside air stream
   • Spring or neoprene isolation

Burner

   • IRI or FM insurance compliance
   • Burner on/off economizer ductstat
   • Low temperature freeze stat
   • High gas pressure regulator

Controls

   • Fused door interlocked disconnect switch
   • Room temperature control
   • ETL listed Recirculating | AR-80 or AR-75
   • ETL listed Variable Air Volume | Demand Air
   • ETL listed high outlet temperature
      system \ H.O.T. 2-speed paint / bake
   • Supply fan VFD
   • DDC control system
   • PLC control system
   • Operation indication lights
   • Circuit analyzer indication lights
   • Clogged filter switch
   • Smoke detector


Direct-Fired Specifications

Non-Tempered

 

Compact Direct-Fired | Non Recirculating

Direct-Fired Non-Recirculating
Direct-Fired Recirculating
Direct-Fired High Outlet Temperature


 

 

 

 

Direct-Fired Drawings

Direct-Fired

HRH

HRD

HRV

HLH

HLD HLV VRH VRV VLH VLV
Compact
Direct-Fired
Non-Recirculating

          NA NA NA NA
Direct-Fired
Non-Recirculating
pdf pdf pdf pdf pdf
Direct-Fired Recirculating pdf pdf pdf       pdf pdf    
Direct-Fired Heating Chilled Water Cooling                    
Direct-Fired Heating Split DX Cooling                    
Direct-Fired Heating Packaged DX Cooling                    
Direct-Fired Heating Direct Evaporative Cooling             NA NA NA NA

Our extensive standard product lines can meet most application requirements, but if you have a unique application or requirement, our product lines can be customized to fit your needs. Titan Air's custom equipment offers flexible performance, construction, components, and controls to meet your specifications and special requirements.

Contact one of our sales engineers and we will work with you to custom design our equipment to fit your exact requirements.

sales@titan-air.com or 715-597-2050

Titan Air is continuously improving their product lines, therefore all dimensions are subject to change without notice. Contact the factory for construction purpose drawings.

 

 

 

 

LITERATURE
BROCHURES

Titan Air  13901 16th Street  Osseo, WI  54758 | 715-597-2050 Office | 715-597-3620 Fax  Copyright © 2012 Titan Air Inc., All Rights Reserved