Steam Summary

Titan Air's steam coil units are designed using a conservative application of coil and blower manufacturers design recommendations to meet a customer's specific requirements. You can be assured of proper heating / cooling and airflow without paying for an undersized or oversized "standard" unit. Standard temperature control options include face & bypass dampers (which can be accompanied by modulating valve control at more mild outside air temperatures), modulating steam valves alone or a combination of on-off valve on pre-heat coil with modulating valve on re-heat coil. For most applications, we utilize 1" steam distributing coils (tube within a tube) that are pitched in the casing for superior freeze resistance. Larger 1" outer tubes provide better freeze resistance than competitors with smaller outer tubes. For lager coils, connection locations and quantities are selected to further enhance freeze resistance. Vertical tubes with pitched horizontal headers are handled easily with our custom equipment capabilities. We have also incorporated integral face/bypass steam coils within our equipment. Custom construction and accessories are also available for special applications. Some examples include corrosion resistant construction and PLC controls for Industrial or Process applications.

pick

Arrangements

Below are standard arrangements. Additional custom arrangements are available upon request.

[pick

 

 

 


Steam Features

Standard Features

Construction

   • ETL Listed
   • Primed welded structural steel base       
   • G-90 Galvanized Casing
   • Single wall access doors
   • Internally mounted motor, burner, and controls
   • Pre-wired, and electrically factory tested
      • Sectioned units may require field assembly,          wiring, and piping
   • Lifting provisions
   • Multiple configurations

Fan & Motor

   • DWDI forward curve industrial type blower(s)
   • Solid turned ground and polished shaft
   • Self aligning bearings
   • Premium E ODP blower motor w/ 1.15
      service factor
   • Motor starter & overload protection
   • Adjustable motor base
   • Variable pitch drive up to 30 HP

Steam Coil

   • Steam coils rated in accordance with ARI       standard 410
   • G-90 galvanized casing
   • Aluminum fins
   • Copper tubes
   • Copper headers

Controls

          • Non-Fused door interlocked disconnect switch
          • Modulating valve or face & bypass discharge air              temperature control, with remote
             set-point & summer-off-winter selector switch
          • Auxiliary contacts for exhaust fan interlock
          • Control voltage transformer

Optional Features

Construction

   • Double wall access doors with extruded       aluminum frames (rated to 8" w.c.)
   • 1” 1.5#, 2” 1.5#, 2” 3#, 2" R-7.7, or 2” R-13       insulation
   • G-90 galvanized, perforated G-90       galvanized, or stainless steel liner
   • Enamel, Epoxy, or Heresite exterior       coating
   • Stainless steel exterior construction
   • Epoxy or Heresite interior coatings
   • Custom configurations and dimensions
   • Built-in or separate chilled water or DX       cooling coil module
   • Built-in or separate direct evaporative       cooler module
   • Packaged DX cooling
   • Flat plate cell energy recovery section
   • Enthalpy wheel energy recovery section

Accessories

   • Mixing Box
   • Intake air hood w/ bird screen
   • V-Bank intake filters
 • 1" or 2" Cleanable
 • Linked panel MERV-8
 • 2" pleated MERV-8
   • Flat bank final filters
 • 2" Pleated MERV-8
 • 4" Pleated MERV-11 to 14
 • 12" Cartridge MERV-11 to 16
 • Bag Filters MERV-9 to 14
 • 12" Carbon odor control
 • 12" HEPA 99.97 to 99.99%
   • Intake damper (standard or low leak)
   • Discharge damper (standard or low leak)
   • Discharge diffuser
   • Roof curb
   • Service platform
   • Service lights
   • GFI service outlet

Fan & Motor

   • BIDW or AFDW Industrial centrifugal fan
   • BISW or AFSW Industrial centrifugal fan
   • Commercial or industrial plenum fan
   • Commercial or industrial plug fan
   • TEFC, Severe Duty or EXP Motors
   • AMCA A, B, or C Spark Resistant
   • Motor and bearings outside air stream
   • Spring or neoprene isolation

Steam Coil

   • Electrofin coating
   • Stainless steel frame
   • Copper fins
   • Steel headers
   • Full stainless steel coils

Controls

   • Fused door interlocked disconnect switch
   • Room temperature control
   • Variable Air Volume
   • Supply fan VFD
   • DDC control system
   • PLC control system
   • Operation indication lights
   • Circuit analyzer indication lights
   • Clogged filter switch
   • Smoke detector


 


   


Steam Specifications

Steam

 

Steam

 


 

 

 

 

 

 

Steam Drawings

Steam

HRH

HRD

HRV

HLH

HLD HLV VRH VRV VLH VLV

Steam Heating

 

 

 

 

 

           
Steam Heating Chilled Water Cooling                    
Steam Heating Split DX Cooling                    
Steam Heating Packaged DX Cooling                    
Steam Heating Direct Evaporative Cooling             NA NA NA NA

Our extensive standard product lines can meet most application requirements, but if you have a unique application or requirement, our product lines can be customized to fit your needs. Titan Air's custom equipment offers flexible performance, construction, components, and controls to meet your specifications and special requirements.

Contact one of our sales engineers and we will work with you to custom design our equipment to fit your exact requirements.

sales@titan-air.com or 715-597-2050

Titan Air is continuously improving their product lines, therefore all dimensions are subject to change without notice. Contact the factory for construction purpose drawings.

 

 

 


LITERATURE

Titan Air  13901 16th Street  Osseo, WI  54758 | 715-597-2050 Office | 715-597-3620 Fax  Copyright © 2012 Titan Air Inc., All Rights Reserved