Indirect Fired Summary

Titan Air's indirect-fired units are used for more than just heating a building. The equipment can be built with the ability to ventilate, cool, humidify, as well as make-up air. The cabinet is designed specifically for each application, resulting in the smallest footprint reasonable. Numerous control options are available for an indirect-fired unit. Controls available range from simple discharge temperature control to more sophisticated building management systems. Other control options include time clocks, indicating lights, and alarms. Mixing dampers, discharge diffusers, cooling coils, and cooling controls are offered as well.

Titan Air's indirect fired units have unique burner and blower options. The two exchanger types are an in-shot type and drum and tube type exchanger. They both work by transferring heat from a gas flame through a stainless steel heat exchanger where the airstream is passed over the heat exchanger warming the air. Specific turn down ratios are available with various configurations and combinations of heat exchangers.

Below are standard arrangements. Additional custom arrangements are available upon request.

pick

Arrangements

Below are standard arrangements. Additional custom arrangements are available upon request.

[pick

 

 

 


Indirect Fired Features

Standard Features

Construction

   • ETL Listed
   • Primed welded structural steel base
   • G-90 Galvanized Casing
   • Single wall access doors
   • Internally mounted motor, burner, and controls
   • Pre-piped, pre-wired, and factory tested
      • Sectioned units may require field assembly,          wiring, and piping
   • Lifting provisions
   • Multiple configurations

Fan & Motor

   • DWDI forward curve industrial type blower(s)
   • Solid turned ground and polished shaft
   • Self aligning bearings
   • Premium E ODP blower motor w/ 1.15
      service factor
   • Motor starter & overload protection
   • Adjustable motor base
   • Variable pitch drive up to 30 HP

Burner

   • 409 S.S. tubular or drum and tube
      indirect-fired heat exchanger
   • ANSI Z83.8 / CSA 2.6 gas train
   • Continuous flame supervision
   • Air proving burner safety switch
   • High gas pressure switch
   • High temperature limit

Controls

          • Non-Fused door interlocked disconnect              switch
          • Discharge air temperature control, with              remote set-point & summer-off-winter              selector switch
          • Auxiliary contacts for exhaust fan interlock
          • Control voltage transformer

Optional Features

Construction

   • Double wall access doors with extruded       aluminum frames (rated to 8" w.c.)
   • 1” 1.5#, 2” 1.5#, 2” 3#, 2" R-7.7, or 2” R-13       insulation
   • G-90 galvanized, perforated G-90 galvanized,       or stainless steel liner
   • Enamel, Epoxy, or Heresite exterior coatings
   • Custom configurations and dimensions
   • Built-in or separate chilled water or DX cooling       coil module
   • Built-in or separate direct evaporative cooler       module
   • Packaged DX cooling
   • Flat plate cell energy recovery section
   • Enthalpy wheel energy recovery section

Accessories

   • Mixing Box
   • Intake air hood w/ bird screen
   • V-Bank intake filters
 • 1" or 2" Cleanable
 • Linked panel MERV-8
 • 2" pleated MERV-8
   • Flat bank final filters
 • 2" Pleated MERV-8
 • 4" Pleated MERV-11 to 14
 • 12" Cartridge MERV-11 to 16
 • Bag Filters MERV-9 to 14
 • 12" Carbon odor control
 • 12" HEPA 99.97 to 99.99%
   • Discharge damper (standard or low leak)
   • Discharge diffuser
   • Roof curb
   • Service platform
   • Service lights
   • GFI service outlet

Fan & Motor

   • BIDW or AFDW Industrial centrifugal fan
   • BISW or AFSW Industrial centrifugal fan
   • Commercial or industrial plenum fan
   • Commercial or industrial plug fan
   • TEFC, Severe Duty or EXP Motors
   • AMCA A, B, or C Spark Resistant
   • Motor and bearings outside air stream
   • Spring or neoprene isolation

Burner

   • 304 S.S. tubular or drum and tube
      indirect-fired heat exchanger
   • IRI or FM insurance compliance
   • Burner on/off economizer ductstat
   • Low temperature freezestat
   • High gas pressure regulator

Controls

   • Fused door interlocked disconnect switch
   • Room temperature control
   • Variable Air Volume
   • Supply fan VFD
   • DDC control system
   • PLC control system
   • Operation indication lights
   • Circuit analyzer indication lights
   • Clogged filter switch
   • Smoke detector

 


   


Indirect Fired Specifications

Indirect Fired

 

Indirect-Fired MUA / AHU

 
Indirect-Fired Air Turnover  


 

Indirect Fired Drawings

Indirect-Fired

HRH

HRD

HRV

HLH

HLD HLV VRH VRV VLH VLV

Indirect-Fired Heating
MUA / AHU

 

 

 

 

 

           
Indirect-Fired Heating Air Turnover NA NA NA NA NA NA        
Indirect-Fired Heating Chilled Water Cooling                    
Indirect-Fired Heating Packaged DX Cooling                    
Indirect-Fired Heating Direct Evaporative Cooling             NA NA NA NA

Our extensive standard product lines can meet most application requirements, but if you have a unique application or requirement, our product lines can be customized to fit your needs. Titan Air's custom equipment offers flexible performance, construction, components, and controls to meet your specifications and special requirements.

Contact one of our sales engineers and we will work with you to custom design our equipment to fit your exact requirements.

sales@titan-air.com or 715-597-2050

Titan Air is continuously improving their product lines, therefore all dimensions are subject to change without notice. Contact the factory for construction purpose drawings.

 

 