Standard Features
Construction
• ETL Listed
• Formed G-90 Galvanized base
< 10,000 CFM
• Primed welded structural steel base
>
10,000 CFM
• G-90 Galvanized Casing
• Single wall access doors
• Internally mounted motor, burner, and controls
• Pre-piped, pre-wired, and factory tested
• Sectioned units may require field assembly, wiring, and piping
• Lifting provisions
• Multiple configurations
Fan & Motor
• DWDI forward curve industrial type blower(s)
• Solid turned ground and polished shaft
• Self aligning bearings
• Premium E ODP blower motor Mw/ 1.15
service
factor
• Motor starter & overload protection
• Adjustable motor base
• Variable pitch drive up to 30 HP
Evaporative Medial
• Rigid cellulose media
• Service vestibule housing contains the submersible pump, float valve, bleed line,
fill / drain / overflow ports, gauges, and
flow control valve
• Stainless steel sump
• Properly designed distribution header,
media supports, and nominal 500 fpm face velocity to prevent moisture carryover
Controls
• Non-Fused door interlocked disconnect switch
• Discharge air temperature control, with remote
set-point & summer-off-winter selector switch
• Auxiliary contacts for exhaust fan interlock
• Control voltage transformer
| Optional Features
Construction
• Double wall access doors with extruded aluminum frames (rated to 8" w.c.)
• 1” 1.5#, 2” 1.5#, 2” 3#, 2" R-7.7, or 2” R-13 insulation
• G-90 galvanized, perforated G-90 galvanized, or stainless steel liner
• Enamel, Epoxy, or Heresite exterior coating
• Stainless steel exterior construction
• Epoxy or Heresite interior coatings
• Custom configurations and dimensions
• Direct fired or indirect fired burner
• Built-in or separate electric coil module
• Built-in or separate hot water or steam coil module
• Flat plate cell energy recovery section
• Enthalpy wheel energy recovery section
Accessories
• Mixing Box
• Intake air hood w/ bird screen
• V-Bank intake filters
• 1" or 2" Cleanable
• Linked panel MERV-8
• 2" pleated MERV-8
• Flat bank final filters
• 2" Pleated MERV-8
• 4" Pleated MERV-11 to 14
• 12" Cartridge MERV-11 to 16
• Bag Filters MERV-9 to 14
• 12" Carbon odor control
• 12" HEPA 99.97 to 99.99%
• Intake damper (standard or low leak)
• Discharge damper (standard or low leak)
• Discharge diffuser
• Roof curb
• Service platform
• Service lights
• GFI service outlet
Fan & Motor
• BIDW or AFDW Industrial centrifugal fan
• BISW or AFSW Industrial centrifugal fan
• Commercial or industrial plenum fan
• Commercial or industrial plug fan
• TEFC, Severe Duty or EXP Motors
• AMCA A, B, or C Spark Resistant
• Motor and bearings outside air stream
• Spring or neoprene isolation
Evaporative Media
• Celdek or Glasdek media
• Remote / auto / fill drain solenoid /
switch kit
• Auto flush / dry timer kit
• Daily dry cycle timer
• Staged humidification / temperature
control for spray booth or other
special applications
• Pump power supply
Controls
• Fused door interlocked disconnect switch
• Room temperature control
• Variable Air Volume
• Supply fan VFD
• DDC control system
• PLC control system
• Operation indication lights
• Circuit analyzer indication lights
• Clogged filter switch
• Smoke detector
|