Air Make-up Unit (AMU)
Achieve optimal ventilation in your industrial or commercial facility with a direct-fired, air make-up unit. Continuously replace exhausted air with 100% fresh heated or cooled air.
Titan Air's direct-fired, make-up air HVAC system provide the most economical method for replacement air. Features include:
Nominal airflow from 1,200 to 120,000 cfm
Non-listed air makeup units larger than 120,000 cfm are also available upon request
Natural gas or LP units
Maximum of 120 degree temperature rise
Factory tested prior to shipping
ETL Listed
|
|
AR Units
Eliminate air stagnation, contamination, and stratification with a Titan Air direct-fired, AR heating system. The AR unit pressurizes the building, improving employee comfort.
Titan Air's AR pressurized heating system creates a slight, even, pressure that effectively controls the infiltration of cold air. The previously heated building air is recirculated and combined with fresh air for proper ventilation. Titan Air's AR direct-fired heating system, when used with properly sized building relief, will eradicate airborne contaminants and reduce indoor air quality problems. Features include:
Pressurized space for a uniformly heated building
110 degree temperature rise on natural gas and 90 degree temperature rise on LP
Factory testing prior to shipping
ETL Listed
Operational cost savings
|
|
High Outlet Temperature (HOT) Units
Obtain the temperatures required to cure today’s sophisticated finishes with a Titan Air direct-fired, high outlet temperature system.
Titan Air business began with building and designing HVAC equipment specifically for the finishing industry. After more than 25 years of experience, Titan Air is uniquely qualified as the industry leader in providing the HOT unit for your finishing application. Features include:
Nominal airflow from 1,200 to 120,000 cfm
Spray and cure modes
Specialized control panels are available to incorporate items such as booth lights,
exhaust fan starters, and PLC controls
Factory testing prior to shipping
ETL Listed
|
|
Demand Air Units
Reduce your utility bill with a Titan Air direct-fired, Demand Air system. Demand Air's VFD allows the unit to consume less gas and electricity because it adjusts for variable exhaust loads. As exhaust increases, Demand Air delivers more air to overcome the decrease in building pressure. As exhaust is reduced, Demand Air responds by delivering less air, resulting in a significant energy savings.
Titan Air was the first to manufacture an ETL Listed, direct-fired heating system utilizing a Variable Frequency Drive (VFD). A pressure control compares indoor and outdoor air pressure and sends a signal to the VFD which varies blower speed to maintain building pressure. This controls cold air infiltration and provides a constant supply of fresh air. Features include:
Nominal airflow up to 120,000 cfm
100 degree temperature rise Variable Frequency Drive (VFD)
Factory testing prior to shipping
ETL Listed
CFM turn down to 30% of total CFM
|
|
Pool Area Units
Create an ideal indoor poolside environment with tempered outdoor air and automatic humidity control. Titan Air’s direct-fired, pool area heating system is cost effective and ideal for cold climates.
Titan Air's pool area system introduces tempered outside air to replace corrosive, humid air exhausted from the pool enclosure. Request more information.
|